Mahr Digimar 817 CLM Height Gages
Measuring System:
- Excellent accuracy and reliability due to the optical incremental measurement system with the double reader head
- Dynamic probing system enabling high repeatability
- Air bearings system for light and smooth movement
- Precise measuring head on stainless steel guideways
- Motorized measuring carriage simplifies measurement runs
- Probe constant remains after the instrument is switched off
- Integrated rechargeable battery with a long operating time span for mains independent measurement
- Temperature compensation with an integrated temperature sensor
Operating and Display Unit:
- Large and clearly defined function keys
- Easy to read background lit graphic LCD display
- Operator guidance with self-explanatory icons / pictograms
- Operator prompts and menus are available in several languages
- Possible to set additional zero points on a work piece
- RS232 and / or USB data output for further data processing
- Save measured data on the integrated USB memory or on a USB stick
- USB interface to connect a compatible USB printer
- Additional measuring instruments with Opto RS232-interface can be connected
- Secure the future due to software update potential
- Automatic stand-by switch mode
- Selectable Auto-off function, without loss of measured values
Supplied with:
- Height Measuring Instrument incl. operating and display unit
- Carrier 817h1
- Probe K6/51
- Setting block 817 eb
- Operating instructions
- Mains power adapter
- USB cable
- Calibration certificate
Specifications:
Order Number | 4429010 | 4429011 | 4429012 | |
Measuring Range | mm / inch | 350 / 14" | 600 / 24" | 1000 / 40" |
Range of application | mm / inch | 520 / 20.37" | 770 / 30.31" | 1170 / 46.06" |
Resolution | mm | 0.01 / 0.005 / 0.001 / 0.0005 / 0.0001 | ||
mergeup | inch | .001" / .0005" / .0001" / .00005" / .00001" | ||
Measuring error | μm | (1.8 + L/600), L in mm | ||
Repeatability | μm | 0.5 (plane) 1 (bore) | ||
Perpendicularity error (elect, adjusted) | μm | frontal ≤ 5 | frontal ≤ 6 | frontal ≤ 10 |
Operating time of rechargeable battery | h | up to 12 | ||
Measuring force | N | 1.0 ± 0.2 | ||
Permissable relative air humidity | % | 65 (non condensed) | ||
Working temperature | °C / °F | 20 ± 1 / 68 ± 1.8 | ||
Operating temperature | °C / °F | 10 . . . 40 / 50 . . . 104 | ||
3-point air cushion, height | μm | ca. 9 | ||
Measuring system | incremental scale with optical reading | |||
Total height | mm / inch | 741 / 29.17" | 985 / 38.78" | 1392 / 54.80" |
Base area (L x W) | mm / inch | 240 x 250 / 9.45" x 9.84" | ||
Weight | kg / lbs | 25 kgs / 55 .15 lbs. | 30 kgs / 66.14 lbs. | 35 kgs / 77.16 lbs. |